FTTH drop cables yellow LSZH 5.0mm optical fiber cable
FTTH drop cable
·Description
The optical fiber unit is positioned in the centre. Two parallel Fiber Reinforced Plastics (FRP) are placed at the two sides. A steel wire as the additional strength member is also applied. Then the cable is completed with a black or color LSZH sheath.
The optical fiber unit is positioned in the centre. Two parallel Fiber Reinforced Plastics (FRP) are placed at the two sides. A steel wire as the additional strength member is also applied. Then the cable is completed with a black or color LSZH sheath.
Quantity
·Description
The optical fiber unit is positioned in the centre. Two parallel Fiber Reinforced Plastics (FRP) are placed at the two sides. A steel wire as the additional strength member is also applied. Then the cable is completed with a black or color LSZH sheath.
·Characteristics
· Special low-bend-sensitivity fiber provides high bandwidth and excellent communication
transmission property;
· Two parallel FRP strength members ensure good performance of crush resistance to protect the
fiber;
· Single steel wire or massagers as the additional strength member ensures good performance of tensile strength;
· Simple structure, light weight and high practicability;
· Novel flute design, easily strip and splice, simplify the installation and maintenance;
· Low smoke, zero halogen and flame retardant sheath.
·Optical Characteristics
G.652 G.655 50/125μm 62.5/125μm
Attenuation
(+20℃) @850nm ≤3.5 dB/km ≤3.5 dB/km
@1300nm ≤1.5 dB/km ≤1.5 dB/km
@1310nm ≤0.45 dB/km ≤0.50 dB/km
@1550nm ≤0.30 dB/km ≤0.50dB/km
Bandwidth (Class A) @850nm ≥500 MHz·km ≥200 MHz·km
@1300nm ≥1000 MHz·km ≥600 MHz·km
Numerical Aperture 0.200±0.015NA 0.275±0.015NA
Cable Cut-off Wavelengthλcc ≤1260nm ≤1480nm
The optical fiber unit is positioned in the centre. Two parallel Fiber Reinforced Plastics (FRP) are placed at the two sides. A steel wire as the additional strength member is also applied. Then the cable is completed with a black or color LSZH sheath.
·Characteristics
· Special low-bend-sensitivity fiber provides high bandwidth and excellent communication
transmission property;
· Two parallel FRP strength members ensure good performance of crush resistance to protect the
fiber;
· Single steel wire or massagers as the additional strength member ensures good performance of tensile strength;
· Simple structure, light weight and high practicability;
· Novel flute design, easily strip and splice, simplify the installation and maintenance;
· Low smoke, zero halogen and flame retardant sheath.
·Optical Characteristics
G.652 G.655 50/125μm 62.5/125μm
Attenuation
(+20℃) @850nm ≤3.5 dB/km ≤3.5 dB/km
@1300nm ≤1.5 dB/km ≤1.5 dB/km
@1310nm ≤0.45 dB/km ≤0.50 dB/km
@1550nm ≤0.30 dB/km ≤0.50dB/km
Bandwidth (Class A) @850nm ≥500 MHz·km ≥200 MHz·km
@1300nm ≥1000 MHz·km ≥600 MHz·km
Numerical Aperture 0.200±0.015NA 0.275±0.015NA
Cable Cut-off Wavelengthλcc ≤1260nm ≤1480nm
Technical Parameters
Fiber Count Cable Diameter
mm Cable Weight
kg/km Tensile Strength
Long/Short Term
N Crush Resistance
Long/Short Term
N/100mm Bending Radius
Static
/Dynamic
mm
1 (2.0±0.2)×(5.0±0.2) 20 60/120 300/1000 15/30
2 (2.0±0.2)×(5.0±0.2) 20 60/120 300/1000 15/30
3 (2.0±0.2)×(5.6±0.2) 21 60/120 300/1000 15/30
4 (2.0±0.2)×(5.6±0.2) 22 60/120 300/1000 15/30
Storage/Operating Temperature : -20℃ to + 60℃
Fiber Count Cable Diameter
mm Cable Weight
kg/km Tensile Strength
Long/Short Term
N Crush Resistance
Long/Short Term
N/100mm Bending Radius
Static
/Dynamic
mm
1 (2.0±0.2)×(5.0±0.2) 20 60/120 300/1000 15/30
2 (2.0±0.2)×(5.0±0.2) 20 60/120 300/1000 15/30
3 (2.0±0.2)×(5.6±0.2) 21 60/120 300/1000 15/30
4 (2.0±0.2)×(5.6±0.2) 22 60/120 300/1000 15/30
Storage/Operating Temperature : -20℃ to + 60℃